B–61863E/15
1. GENERALPMC OPERATION (CRT/MDI)
425
The PMC–PA1 and PA3 contained in the Power Mate have a sequence
program called the “standard ladder” in their ROM to operate the Power
Mate without creating a sequence program.
Operation)
Parameter in the Power Mate
#7 #6 #5 #4 #3 #2 #1 #0
8703 FLA
#0 (FLA) = 0 : The FANUC standard ladder is not used.
1 : The FANUC standard ladder is used.
(1) Set bit 0 (FLA) of NC parameter 8703 to 1.
This generates alarm 000 (power–off request) in the Power Mate.
(2) Turn off the power, then turn it on again.
If the PMC contains a sequence program (PMC alarm ER22
PROGRAM NOTHING does not occur), turn on the power while
clearing the sequence program (pressing X and O).
(3) The FANUC standard ladder is loaded.
CAUTION
If the sequence program is not cleared in the PMC, the
FANUC standard ladder is not loaded. The existing
sequence program remains.
See Part IV, ”PMC–NB6 Manipulation” for an explanation of how to
operate the FS15i PMC–NB6.
See Part V, ”PMC–SA1/SB7 Manipulation” for an explanation of how to
operate the FS16i/18i/21i–B PMC–SA1/SB7.
1.4
LOADING THE
STANDARD LADDER
(FOR Power Mate–D/F
PMC–PA1 AND PA3)
1.5
FS15i PMC–NB6
OPERATING
PROCEDURE
1.6
FS16i/18i/21i–B
PMC–SA1/SB7
OPERATING
PROCEDURE