B–61863E/15
4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
PMC OPERATION (CRT/MDI)
477
CAUTION
1 The Data for Controlling Nonvolatile Memory(K16)
Refer to I–6.1(4)”Nonvolatile Memory Control”.
2 The Data for PMC Management Software(K17,18,19)
Be careful of using the following KEEP RELAYs, because
they are used by PMC Management Software.
The Data for PMC Management Software
Model PA1 PA3
PMC control software data 1 K17 K17
PMC control software data 2 K18 K18
Reserved K19 K19
Model SA1 SA2
PMC control software data 1 K17 K17
PMC control software data 2 K18 K18
Reserved K19 K19
Model SB SB2
PMC control software data 1 K17 K17
PMC control software data 2 K18 K18
Reserved K19 K19
Model
SA3/
SA5
SB3/
SB5
SB4/
SB6
PMC control software data 1 K17 K17 K900
PMC control software data 2 K18 K18 K901
PMC control software data 3 K19 K19 K902
Reserved K903
to
K909
Model SC SC3 SC4
PMC control software data 1 K17 K17 K900
PMC control software data 2 K18 K18 K901
PMC control software data 3 K19 K19 K902
Reserved K903
to
K909
Model NB NB2
PMC control software data 1 K17 K900
PMC control software data 2 K18 K901
PMC control software data 3 K19 K902
Reserved K903
to
K909
PMC control software data 1 (K17 or K900)
DTBLDSP ANASTAT TRCSTART MEMINP SELCTMDL AUTORUN PRGRAM LADMASK
K17
or
K900
#7 #6 #5 #4 #3 #2 #1 #0