2. SETTING FUNCTION
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
862
NOTE
If this bit is turned on, setting in multi–language
alarm/operator message display function setting screen is
overwritten by the value of K916–K919.
Please set K916–K919 previously before the bit is turned
on.
#3 NOEOUTPUT 0 : Contents of E address is output when PMC parameter is output at I/O
screen.
1 : Contents of E address is not output when PMC parameter is output at
I/O screen.
: This flag is effective on PMC–SB7.
#2 IOCHK 0 : I/O Link connection check function is enabled.
(Caution2) 1 : I/OLink connectino check functino is disabled.
: This flag is effective on PMC–SB7.
#1 IOSELSCN 0 : Setting screen for the selectable I/O Link assignment functino is
disabled.
1 : Setting screen for the selectable I/O Link assignment functino is
enabled.
: This flag is effective on PMC–SB7.
#0 OVRRIDE 0 : Override function is disabled.
1 : Override function is enabled.
: This flag is effective on PMC–SB7.
CAUTION
1 Be sure to set any unused areas to 0.
2 When the I/O devices are linked on the several abnormal
status, for example, a failure of the I/O devices, a failure of
the I/O device’s connection and a change of the setting of
the I/O devices by unintentional operation, there is
possibility that the machine may not work normally. If this
function is effective, it is possible to inspect the abnormality
of the I/O devices in power on. It is recommended that this
setting is set to initial value (0) to troubleshoot the I/O
devices easily.
K916–
K917
message shift start address
Specify bit offset from A0.0 for start address of message shift. Bit offset
of Ax.y can be calculated as x 8+y.
e.g.) A0.0 → 0 8+0 = 0
A249.7→ 249 8 + 7 = 1999
: This area is effective when K906.4=1.