4. PMC DATA SETTING AND
DISPLAY (PMCPRM)
B–61863E/15
PMC–NB6 MANIPULATION
688
(1)Special use area ( K900 – K909)
PMC type PMC–NB6
Special use area 1 K900
Reserved K901 – K909
#7
DTBL DSP
K900
#6 #5 #4
MEMINP
#3 #2
AUTORUN
#1
PRGRAM
#0
LADMASK
#7 DTBLDSP 0 : The Data Table Controlling Data screen is displayed.
1 : The Data Table Controlling Data screen is not displayed.
#4 MEMINP 0 : The status of signals is not allowed to be modified.
1 : The status of signals is allowed to be modified.
This setting is effective for the following screens.
Embedded PMC:
* LADDER Diagram Monitor screen (Forced I/O function)
FANUC LADDER–II and Ladder Editting Package
* Signal Status Screen (Online function)
#2 AUTORUN 0 : Sequence program starts automatically at power on.
1 : Sequence program starts by pressing of soft key [RUN]
#1 PRGRAM 0 : Embedded debug function is unavilable.
1 : Embedded debug function is avilable.
This setting is effective for the following screens and functions
Embedded PMC:
* LADDER Diagram Editor screen, I/O Unit Allocation Editor screen
* I/O screen
FANUC LADDER–II and Ladder Editting Package
* Ladder transfer function
* Ladder Editor Screen (Online function)
#0 LADMASK 0 : Ladder diagram is displayed.
1 : Ladder diagram is not displayed.
This setting is effective for the following screens and functions
Embedded PMC:
* LADDER Diagram Editor screen, I/O Unit Allocation Editor screen
* I/O screen
FANUC LADDER–II and Ladder Editting Package
* Ladder transfer function
* Ladder Editor Screen (Online function)
CAUTION
Set always ”0” to any other relays in Special us area than
mentioned above, to prevent unexpected behavior of PMC.