B–61863E/15
5. LADDER DIAGRAM EDITOR
FUNCTION (PMC–SB7)
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
925
Some functional instructions may cause the ladder program to take a long
time to stop or make it unable to stop, if their ACT or RST condition
remains on for no apparent reason. If the ladder program does not stop,
all operations aimed at changing the ladder program will take longer to
end or will never end.
To avoid such problems, when you code a ladder program using
functional instructions, you need to design the ladder structure based on
a thorough understanding of the control conditions of the individual
instructions you use.
Listed below are typical cases in which the ladder program will not stop.
D A low–speed window function is used for a WINDR or WINDW
functional instruction, and its ACT condition remains on.
D In an EXIN or AXCTL instruction, not only the ACT condition but
also the RST condition remain on.
D The jump destination label is present before a JMPB instruction.
D In a JMPC instruction, the jump destination label points to the same
JMPC instruction.
If the ladder program takes long to stop or does not stop for any of these
reasons, the following operations will be affected.
1. Stopping the ladder program using a soft key on the screen.
2. Reading a new ladder program from a memory card or other medium,
by using the data input and output screen.
3. Updating the ladder program with changes made using the ladder
diagram edit screen.
If any of the above phenomena occurs, the functional instruction causing
the problem needs to be fixed. Check the functional instructions
mentioned above to see whether there is any ACT or RST condition
remaining on, and correct the ladder program according to the following
procedure.
1. Put the machine in safe condition and turn off the power of the NC.
2. Turn on the power of the NC while holding down the ”CAN” and ”Z”
keys simultaneously, to restart the NC with the ladder program halted.
3. In the ladder diagram edit screen, redesign the logic associated with
the problematic functional instruction. When done, set the ACT or
RST condition to off. If the same operation is repeating because of an
inadequate JMPB or JMPC instruction, review the jump condition
and, if necessary, change the ladder structure.
4. Write the resulting logic to flash ROM using the I/O screen.
5. Run the ladder program.
If the ladder program does not stop or cannot be changed even after you
make the correction, there may be other functional instructions that have
the same condition settings. Check for other functional instructions
having the same condition settings, besides the one you have corrected,
and repeat the above procedure to correct them all.
5.11
NOTE ON