B–61863E/15
4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
PMC OPERATION (CRT/MDI)
489
(b) OVERRIDE mode of the forced input/output function
D Set OVERRIDE mode by using the soft key or by entering
0 or 1 followed by the <INPUT> key.
PMC PRM (OVERRIDE) MONIT RUN
OVERRIDE ENABLE = 0 (0:NO 1:YES)
[ NO ] [ YES ] [ ] [ PREV ] [ NEXT ]
OVERRIDE ENABLE 0 : OVERRIDE mode is disabled.
1 : OVERRIDE mode is enabled.
CAUTION
If the setting of this parameter is modified, the new setting
becomes effective when the power is next turned on. After
this parameter has been modified, the power must be
turned off then back on.