B–61863E/15
11. PMC PROGRAMMER (DPL/MDI)
(ONLY FOR THE Power Mate)
PMC PROGRAMMER (CRT/MDI)
637
D Parameter in the Power Mate–D/H (No.0101#6)
#7 #6 #5 #4 #3 #2 #1 #0
0101
#6 = 0 : On–line monitor driver is not used.
1 : On–line monitor driver is used.
NOTE
In case of Power Mate–D two–path control, only the
parameter of first path side is effective.
When either of the following conditions consists, the on–line monitor
driver is started.
DParameter “RS–232C” is “USE”
DBit 6 of parameter No.0101 is “1”
CAUTION
1 The on–line monitor driver occupies the line while it is
operating.
In this state, other input/output functions cannot use the
line.
If other input/output functions use the line, it is necessary to
display the above–mentioned parameter and stop the
on–line monitor driver.
2 While the on–line monitor driver is operating, the following
functions cannot be used.
D[PMCLAD], [I/O], [EDIT], [SYSPRM] on CRT/MDI
D[EDIT], [SYSTEM PARAM], [I/O] on DPL/MDI
3 In case of operating NC, the screen display of NC(Position,
etc.) might be slow when using input/output functions(Load
from PMC, Store to PMC, etc.). There is no problem in the
operation of NC. It is recommended to using input/output
functions while NC is not operating.
4 When the screen made by C language executor is
displayed, the communication speed decreases. It is
recommended to use input/output functions after moving to
other screens(Position, etc.).