B–61863E/15
2. SETTING FUNCTION
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
847
MESSAGE SHIFT VALUE
Enter a desired message display request bit shift amount.
A value from 0 to 1999 can be entered. The initially displayed value
is 0.
Entered data is maintained even after the power is turned off.
MESSAGE SHIFT START ADDRESS
Enter a shift start bit address in the message display request bit area.
Valid range of A–address can be entered. The initial value is A0.0.
Entered data is maintained even after the power is turned off.
NOTE
1 Data entered for MESSAGE SHIFT START ADDRESS is
valid only when a value other than 0 is entered for
MESSAGE SHIFT VALUE.
2 When K906.4=1, setting in keep relay, K916–K919 is
effective for a multi–language alarm/operator message
display function. In this case, the screen shows the setting
in K916–K919. Moreover, the setting that is modified in this
screen is written to keep relay.(SHIFT VALUE is written to
K918–K919, START ADDRESS is written to K916–K917.)
2.3
MULTI–LANGUAGE
ALARM/OPERATOR
MESSAGE DISPLAY
FUNCTION SETTING
SCREEN