5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
206
This instruction ORs the input data and the logical sum data and
transfers the result to the destination.
OR
Input data Logical sum data
Output data
Fig.5.17.2 shows the expression format of MOVOR.
MOVOR
(SUB 28)
ACT
ffff
Input data
address
ffff
Logical
sum data
address
ffff
Output
address
Fig. 5.17.2 Expression format of MOVOR
(a) Command (ACT)
ACT=0: Do not execute MOVOR.
ACT=1: Execute MOVOR.
(a) Input data address
Specifies the address for the input data.
(b) Logical sum data address
Specifies the address of the logical sum data with which to OR the
transferred data.
(c) Output address
This is the address to contain the logical sum obtained. It is also
possible to obtain the logical sum (OR) of the input and the logical
sum data and output the result in the logical sum data address. For
this, you must set the logical sum data address for the output address.
5.17
MOVOR
(DATA TRANSFER
AFTER LOGICAL
SUM)
5.17.1
Function
5.17.2
Format
5.17.3
Control Conditions
5.17.4
Parameters