2. SETTING FUNCTION
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
858
i) If you want to prohibit completely operator from accessing the
sequence program;
D PROGRAMMER ENABLE
(PMC–SB7: K900.1, PMC–SA1: K17.1) ”NO”
D HIDE PMC PROGRAM
(PMC–SB7: K900.0, PMC–SA1: K17.0) ”YES”
D EDIT ENABLE
(PMC–SB7: K901.6, PMC–SA1: K18.6) ”NO”
D ALLOW PMC STOP
(PMC–SB7: K902.2, PMC–SA1: K19.2) ”NO”
ii) If you want to allow operator only monitoring the sequence program;
D PROGRAMMER ENABLE
(PMC–SB7: K900.1, PMC–SA1: K17.1) ”NO”
D HIDE PMC PROGRAM
(PMC–SB7: K900.0, PMC–SA1: K17.0) ”NO”
D EDIT ENABLE
(PMC–SB7: K901.6, PMC–SA1: K18.6) ”NO”
D ALLOW PMC STOP
(PMC–SB7:K 902.2, PMC–SA1: K19.2) ”NO”
NOTE
Please use the password function of sequence program for
particular operator. Please refer to FANUC LADDER–III
operator’s manual B–66234EN ”5.4 PROTECING LADDER
PROGRAMS BY PASSWORD”
iii) If you want to allow operator monitoring and editing the sequence
program;
D PROGRAMMER ENABLE
(PMC–SB7: K900.1, PMC–SA1: K17.1) ”NO”
D HIDE PMC PROGRAM
(PMC–SB7: K900.0, PMC–SA1: K17.0) ”NO”
D EDIT ENABLE
(PMC–SB7: K901.6, PMC–SA1: K18.6) ”YES”
D ALLOW PMC STOP
(PMC–SB7: K902.2, PMC–SA1: K19.2) ”NO”
NOTE
Please use the password function of sequence program for
particular operator. Please refer to FANUC LADDER–III
operator’s manual B–66234EN ”5.4 PROTECING LADDER
PROGRAMS BY PASSWORD”.
iv) If you want to allow operator monitoring and editing the sequence
program which requires stop of ladder;
D PROGRAMMER ENABLE
(PMC–SB7: K900.1, PMC–SA1: K17.1) ”NO”
2.7
EXAMPLE FOR
SETTING
PARAMETERS