B–61863E/15
3. ADDRESS
PMC SEQUENCE PROGRAM
97
(a) If DO alarm detection is not used
D No manual pulse generator:
Input X = “CM12I” and output Y = “CM08O”
D One manual pulse generator:
Input X = “CM13I” and output Y = “CM08O”
D Two manual pulse generators:
Input X = “CM14I” and output Y = “CM08O”
D Three manual pulse generators:
Input X = “CM15I” and output Y = “CM08O”
(b)If DO alarm detection is used
D Input X = “CM16I” and output Y = “CM08O” no matter how
many manual pulse generators are used
Refer to the following manuals for an explanation how the operator’s
panel I/O module signals are mapped:
D “FANUC Series 16i/18i Connection Manual (Hardware)”
B–63003EN
D “FANUC Series 21i Connection Manual (Hardware)” B–63083EN
D “FANUC Series 15i Connection Manual (Hardware)” B–63323EN
D “FANUC Power Mate i D/H Connection Manual (Hardware)”
B–63173EN
(1)Operator’s panel I/O module
(A20B–2002–0470 supporting matrix inputs)
Operator’s panel I/O
module
JD1B
JD1A
16 general–purpose input points + 56 matrix input points
56 matrix output points
(a) If DO alarm detection is not used
D No manual pulse generator:
Input X = “CM12I” and output Y = “CM08O”
D One manual pulse generator:
Input X = “CM13I” and output Y = “CM08O”
D Two manual pulse generators:
Input X = “CM14I” and output Y = “CM08O”
D Three manual pulse generators:
Input X = “CM15I” and output Y = “CM08O”
(b)If DO alarm detection is used
D Input X = “CM16I” and output Y = “CM08O” no matter how
many manual pulse generators are used
(2)Operator’s panel I/O modules
(A20B–2002–0520 and A20B–2002–0521)
Operator’s panel I/O
module