B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1196
[Completion codes]
0 : Modal information has been read normally.
3 : Invalid data is specified as the data number.
4 : Invalid data is specified as the data attribute.
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
32
(See the explanation above.)
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 2, 6, 2*n, 6*m)
(Data number)
N
(N: Input data)
(Data attribute)
M
(M: Input data)
Modal data for G function (2 bytes) See the data format for the G function.
The upper byte must always be set to 0.
Value
8
10
(Data attribute)
M
(M: Input data)
Data part of modal data for other than
G function(4 bytes)
See the data format for other than the
G function.
Value
14
Flag part of modal data for other than
G function(2 bytes)
See the flag format of the data for other
than the G function. The upper byte
must always be set to 0.
Or
L = 2 : G function
L = 2*n : All data for G function
L = 6 : Other than G function
L = 6*m : All data for other than G function
(n: Number of groups for the G function)
(m: Number of types other than for the G function)
When all data items are specified to be read, the data items are all output
simultaneously in the order specified in the above data table.