I. EDITING FOR Power Mate–MODEL D
(PMC–PA1/PA3)
B–61863E/15
APPENDIX
1512
FANUC Power Mate–MODEL D can set only COUNTER DATA TYPE.
The meaning of this parameter is same as PMC–SA1/SA2.
PMC SYSTEM PARAMETER
COUNTER DATA TYPE = BINARY/BCD
[BINARY] [ BCD ] [ ] [ ] [ ]
Fig. I.3.2 PMC–PA1 or PA3 System Parameter Screen
When the following condition is satisfied, the CONDNS key will be used
in FANUC Power Mate–MODEL D.
· Some unused area remain by repeating the addition or the deletion
of the symbol/comment and the message in the memory.
· Ladder might be able to be made more by compressing the unused
area by pushing [CONDNS] key when the memory is insufficient
while ladder is added.
[Example: When you want to expand ladder area by deleting
symbol/comment data at the memory status Fig.I.3.3 (a)]
(1) Delete symbol data(0.2KB).
(2) Push [CONDNS] key.
(3) The memory status becomes as Fig.I.3.3 (c) and LADDER can be
edited more.
NOTE
1 Sequence program area in Fig. I.3.3 (a) – (c) is 64KB.
2 The underlined memory in Fig. I.3.3 (a) – (c) is the same as
the memory display of the TITLE screen.
3 The symbol/comment area in Fig. I.3.3 (a) is 20KB (Unused
area 0.9KB is contained.)
4 In case of deleting message and expending another area,
it is as same as this example.
I.3.2
Specification and
Display of System
Parameters (SYSPRM)
I.3.3
Condense