NOTE
1 This is the number of ladder steps for the program only with
basic instructions. The use of functional instructions may
vary the number of ladder steps.
2 The size of a symbol and that of a comment are fixed 32KB.
The size of message is fixed 2.1KB. The maximum size of
a symbol and that of a comment are 64KB each.
3 When extended memory is not specified in the 4082 series
(ordering drawing No.: A02B–0210–H020 or
A02B–0210–H022), the program capacity is 64KB.
4 These have no limit of size for each. However, the total size
of sequence program (the sum total of ladder,
symbols/comments, messages, etc.) never exceed the
storage size of sequence program. The size of them
influences the capacity of others.
5 Output points of I/O card in 4082 or 4084 series are following;
PMC–SA1 : 64points, PMC–SA3 : 64points
6 As values indicated with an asterisk (*) in the table, former
versions of the programming manual and brochure have
listed the mean processing time of basic commands, but this
manual lists the execution time for one step. The actual
ladder program execution performance (speed) of each
PMC has not been changed.
7 Application PMC for FANUC Series 21–B loader control
function is PMC–SA1.