Connection Log Meanings and countermeasures
SnpErr:PDU=m,n,[x] date time
SnpErr:PDU=n,[x] date time
SnpErr:TaskTimeOut[x] date time
An error has occurred during the online communication.
m, n : Online communication information that is internal information of a system.
x : Error information
6001 PMC does not support the Ethernet.Confirm the Series/Edition of PMC
software.
6003 Unsupported command data was received.Confirm the Series/Edition of
Ethernet board software.
6004 There was an error in command dataConfirm the Series/Edition of
Ethernet board software.
6005 PMC does not receive command data.Confirm the communication sta-
tus at the online setting screen of PMC.
6010 PMC does not receive command data.Confirm if ”HIGH SPEED
I/F=USE” is selected and other application is not connected at the online
setting screen of PMC.
6011 Time–out error occurred at PMC.Increase the value of ”Time Out” in
[Network Address] of [Communication] menu for FANUC LADDER–III or
Ladder Editing Package.
6012 PMC does not receive command data because it is busy for proces-
sing.Confirm the communication status at the online setting screen of
PMC.
6013 Time–out error occurred at PMCIncrease the value of ”Time Out” in
[Network Address] of [Communication] menu for FANUC LADDER–III or
Ladder Editing Package.
6101 PMC received an unsupported function code.Confirm the Series/Edition
of PMC software.
date : The date when the error occurred.
Ex.) ”0126” means January 26th.
time : The time when the error occurred.
Ex.) ”1623” means 4:23 PM.