3. PMC I/O SIGNAL DISPLAY AND
INTERNAL RELAY DISPLAY
(PMCDGN)
B–61863E/15
PMC OPERATION (CRT/MDI)
456
The I/O Link connecting check screen displays the types and ID codes of
the connected I/O devices for each group. When I/O device is not
connected, ”NO I/O DEVICE” is displayed.
If there is a problem of input or output signals for I/O devices, check
connection of I/O Link by referring to this screen.
(1) When CNC hardware dose not support the I/O Link expansion
function.
PMC I/O LINK(1/1)
CHANNEL 1
GROUP ID KIND OF UNIT
00 80 CONNECTION UNIT
01 82 OPERATOR PANEL
02 84 I/O UNIT MODEL A
03 96 CONNECTION UNIT
04 4A POWER MATE
Fig. 3.8.1 (a) Example of the I/O Link screen
Table 3.8.1 I/O devices and ID codes
Displayed I/O device name ID Actual I/O device
CONNECTION UNIT 80 Connection unit
OPERATOR PANEL 82 Operator’s panel connection unit
I/O-B3 83 Expanded I/O B3
I/O UNIT MODEL A 84 to 87 I/O Unit MODEL A
I/O UNIT MODEL B 9D to 9E I/O Unit MODEL B
POWER MATE 4A Power Mate
FANUC SERVO AMPLIFIER UNIT ß
series (I/O Link OPTION)
CONNECTION UNIT 96 I/O Link connection unit
I/O MODULE A9 to AA Distributed I/O
OTHER UNIT Other than above
The screen displayed like fig.3.8.1 (a) means that the I/O devices are
composed like following fig.3.8.1 (b).
3.8.1
I/O Link Connecting