4. OPERATION
B–61863E/15
PMC PROGRAMMER (SYSTEM P series)
1102
(1) Transfer of sequence program into PMC–SA1/SA2/SB/SC
A generated sequence program is transferred into
PMC–SA1/SA2/SB/SC.
Connect SYSTEM P series to CNC by using a Reader/Puncher
interface cable for the connection method and places, see Section 3.2.
Steps 1 to 6 show the operation on the CNC side.
1 Pressing soft keys <SYSTEM> and [PMC] displays the PMC
screen. Steps 2 to 4 below must be performed when [I/O] is not
displayed on the PMC screen. For a 9–inch CRT, press soft key
[NEXT] to check that [I/O] is not on the screen.
2 Pressing soft keys [PMCPRM] and [KEEPRL] on the PMC
screen displays the keep relay setting screen.
3 Set K17.1 to 1 on the keep relay setting screen.
4 Pressing soft key [RETURN] displays the PMC screen.
5 On the PMC screen, pressing soft key [I/O] displays the I/O
screen. For a 9–inch CRT, press soft key [NEXT] before pressing
soft key [I/O].
6 Pressing soft key [EXEC] on the I/O screen puts the system in the
EXECUTING state.
7 Turn on F8 key from the SYSTEM P series menu screen. (Also
turn on F12 key when the C language program is included.)
8 Key in menu number “5 <NL>”.
Now, the program transfer is started.
In SYSTEM P series, the transfer screen is displayed and the
transfer counter is counted up. After transfer, the screen is reset
to menu screen. In CNC screen, the COUNTER display is
counted up.
i) When an alarm 31 occurs on SYSTEM P series screen;
Cause 1 : Reader/Puncher interface cable is defective.
Remedy : Use the specified cable.
Cause 2 : Reader/Puncher interface connector is not
connected to correct channel SYSTEM P series.
Remedy : Connect the connector correctly.
ii) When the transfer counter of SYSTEM P series screen is
counted up and normally terminated, but data are not
transferred to the PMC RAM correctly;
Cause 1 : Reader/Puncher interface connector is not
connected to CNC.
Remedy : Connect it correctly.
Cause 2 : CNC screen is not set to ”I/O of PMC” screen.
Remedy : Set the I/O screen by the soft key.
Cause 3 : An error occurs in ACI channel due to a certain
cause.
Remedy : Turn off the power supply once, and turn it on
again.
4.5.3
ROM Format Program
*Procedure when a
program cannot be
transferred from
SYSTEM P series to RAM
of PMC