5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
292
Example 3:
As common alarm messages, English message data is displayed
with A0.0 through A9.7. Operator messages are set starting at
A10.0 in the order of Japanese, English, Italian, German and so
on, with 40 successive messages assigned to each language. For
these messages, German message data is displayed.
Set the parameters as follows:
MESSAGE SHIFT VALUE : 120 (40 x 3)
MESSAGE SHIFT START ADDRESS : A10.0
(MESSAGE SHIFT VALUE =
0:Japanese/40:English/80:Italian/120:German)
Manipulate A10.0 through A14.7 with the ladder.
When any of A0.0 to A9.7 is turned on, the message
corresponding to the bit is displayed.
Message table
A0.0 English A (ALARM)
A0.1 English B (ALARM)
A0.2 English C (ALARM)
A10.0
Japanese 1
(OPE)
A10.1
Japanese 2
(OPE)
A15.0
English 1
(OPE)
A15.1
English 2
(OPE)
A20.0
Italian 1
(OPE)
A20.1
Italian 2
(OPE)
A25.0
German 1
(OPE)
A25.1
German 2
(OPE)
::
When A0.1 is turned on, English B
is displayed.
When A10.0 is turned on,
German 1 is displayed.
When A10.1 is turned on,
German 2 is displayed.
(The message data is shifted by
120 bits).
Am.n :
(c) Notes
The same message number should be assigned to a message in each
language that has the same meaning.
Message table
A0.0 1000 English A (ALARM)
A0.1 1001 English B (ALARM)
A10.0 1000 Japanese 1 (OPE)
A10.1 1001 Japanese 2 (OPE)