B–61863E/15
4. PMC DATA SETTING AND
DISPLAY (PMCPRM)
PMC–NB6 MANIPULATION
685
It is possible to enter data continuously on each of the timer, counter, keep
relay, and data table screens. After continuous data entry, the cursor
appears at the bottom of the most recently entered data.
D Entry
(1)Use “;” (EOB) as a data delimiter.
(Example) “100;200;300;” + “INPUT” key
(2)Use “;=” to enter the same value as the previous data.
(Example) Entering “100;=;=;200;=” + “INPUT” key causes the
following data to be entered: 100,100,100,200,200
(3)Use “;;” to skip an address for entry.
(Example) Entering “100;;200;” + “INPUT” key causes the
second data item to be skipped from entry.
This screen is used to set and display the timer values for the machine
instruction timers (SUB3).
Table contents
D NO.: Counter number specified for a machine instruction
counter
D ADDRESS: Address referenced by a sequence program
D DATA: Timer value
Timer number Minimum timer value
that can be specified
Maximum timer value
that can be specified
1 to 8 48ms 1572.8 s
9 to 150 8ms 262.1 s
4.3
CONTINUOUS DATA
ENTRY
4.4
TIMER SCREEN
(TIMER)