B–61863E/15
4. OPERATIONPMC PROGRAMMER (SYSTEM P series)
1095
6 The following procedure is the same as in 4.4.1 2) 4.
7 A file name is inputtable up to maximum 17 characters. All
characters on the SYSTEM P series keyboard are employable for
this entry. The kinds of capitals are not limited.
“@” (at mark) shows a file name input identifier. Key in it just
before the file name as shown in example $$ without fail.
CAUTION
If sequence program instructions are sequentially entered
while a sequence program is loaded in the SYSTEM P
series memory, the instructions are entered into the
SYSTEM P series memory following the previously loaded
program. Clear SYSTEM P series memory, if a new program
is entered from the floppy. (see 4.7)
The SYSTEM P series memory is cleared by turning off the
SYSTEM P series power supply.
(1) Transfer of sequence program from the PMC–SA1/SA2/SB/SC
The created sequence program is transferred from the
PMC–SA1/SA2/SB/SC.
First, connect the SYSTEM P Series and the CNC with a
Reader/Puncher interface cable. For the method and location of
connection, refer to the section ”3.2 Configuration devices and their
connection”. In the following procedure, operations 1 to 6 are NC
side operations.
The keys enclosed in [ ] are soft keys.
1 Pressing soft keys [SYSTEM] and [PMC] displays the PMC
screen. Steps 2 to 4 below must be performed when [I/O] is not
displayed on the PMC screen. For a 9–inch CRT, press soft key
[NEXT] to check that [I/O] is not on the screen.
2 Pressing soft keys [PMCPRM] and [KEEPRL] on the PMC
screen displays the keep relay setting screen.
3 Set K17.1
to 1 on the keep relay setting screen.
4 Pressing soft key [RETURN] displays the PMC screen.
5 On the PMC screen, pressing soft key [I/O] displays the I/O
screen. For a 9–inch CRT, press soft key [NEXT] before pressing
soft key [I/O].
6 Pressing soft key [EXEC] on the I/O screen puts the system in the
EXECUTING state.
7 Turn on the F8 key on the SYSTEM P series menu screen. (Turn
on the F12 key at the same time when the C–language program
is included.)
8 If the menu number ‘3 [NL]’ is keyed in, the message shown
below will be displayed. PMC–SA1/SA2/SB is not displayed.
Key in the type of ROM module to be used from now on. (Refer
to Note 1 when selecting ROM module B, C or D.)
4.4.2
ROM Format Program