5. SETTING MENU (SETING)
B–61863E/15
PMC–NB6 MANIPULATION
694
If PROGRAMMER ENABLE is set to YES on the GENERAL screen,
the [ONLINE] soft key appears on the setting menu screen. Clicking this
soft key displays the following screen.
Menu descriptions
D CPU ID
The CPU ID value is displayed. The value can also be entered here,
but its entry is usually not necessary.
D RS–232C (prompt)
USE: An RS–232C port can be connected to FANUC
LADDER–II.
NOT USE: No RS–232C port is used.
Note) If no RS–232C is to be connected to FANUC LADDER–II,
select NOT USE.
D CHANNEL
A channel number to be used is displayed. The number can also be
entered.
D BAUD RATE
300: A baud rate of 300 is specified.
600: A baud rate of 600 is specified.
900: A baud rate of 900 is specified.
1200: A baud rate of 1200 is specified.
2400: A baud rate of 2400 is specified.
4800: A baud rate of 4800 is specified.
9600: A baud rate of 9600 is specified.
19200: A baud rate of 19200 is specified.
D PARITY
NONE: No parity is specified.
ODD: Odd parity is specified.
EVEN: Even parity is specified.
5.3
SCREEN FOR
SETTING/DISPLAYIN
G ONLINE MONITOR
PARAMETERS
(ONLINE)