2. SEQUENCE PROGRAM
B–61863E/15
PMC SEQUENCE PROGRAM
46
1st level
2nd level
NC processing
8ms 8ms 8ms
Division 1Division 1 Division nDivision 2
1.25ms 1.25ms 1.25ms
Fig. 2.3 (b) Sequence in which the Sequence Program Is Executed (PMC–SA1, –SA2, –SB and –SB2)
1st level
2nd level
3rd level, program execution,
and displaying the PMC screen
8ms 8ms 8ms
Division 1Division 1 Division nDivision 2
5ms 5ms 5ms
Fig. 2.3 (c) Sequence in which the Sequence Program Is Executed (PMC–SC)
(2) 1st level sequence part
Only short–width pulse signals are processed. These signals include
emergency stop, overtravel of each axis, reference point return
deceleration, external deceleration, skip, measuring position arrival
and feed hold signals.
(3) 3rd level sequence
The purpose of the 3rd level sequence is to execute such programs
as display processing or control status monitor having no direct
relation to the machine control (operator message, alarm display,
etc.), to lighten the load of the 2nd level program having a direct
relation to the machine control by transferring former programs to the
3rd level, and to shorten the PMC execution time (cycle time).
For PMC–RC, when 3rd level program is not used, command SUB
48 (END3) following SUB 2 instruction.
(4) Divided system and undivided system
There is a model can use the divided system and undivided system
among the PMCs. In the divided system, a ladder program is divided
before being executed if all ladder program run regardless of the
sequence state (see Fig. 2.3 (d)).
For an actual ladder program, not all ladder program run. The PMC
cannot therefore be used effectively.
The PMC can execute the ladder program in the system for terminating
one cycle of the program using the time to execute the actual ladder
program (undivide system) as well as in the divided system.
The time required for the one cycle can be reduced by the effective
use of jump instructions in the ladder program.
Since the sequence using many functional instructions requires a lot
of processing time, the undivided system should be specified so that
the PMC is used more effectively (see Fig. 2.3 (e)).
To operate the PMC in the undivided system, set system parameter
IGNORE DIVIDE CODE to YES.
The PMC model usable only the undivided system, does not have
setting system parameter IGNORE DIVIDE CODE. It is always