B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1171
[Description]
When the CNC is in the alarm status, the alarm status data can be read.
The following alarm status data can be read:
(1) First byte of alarm status data
PS1
PS2
PS3
PS
OTS
OH
SV
MALM
76543210
PS1 : P/S alarm 100 (PWE (parameter write enable) is set to 1.)
PS2 : P/S alarm 000 (Turn off the power before continuing operation.
Some parameters activate this alarm status when they are
written.)
PS3 : P/S alarm 101 (The part program recording area is disordered.
This alarm is activated when the power to the CNC is turned off
during part program editing or reading of a machining program.
To release the alarm, then press the RESET key while holding
down the PROG key.)
PS : A P/S alarm other than the above alarm is generated
OTS : Stroke limit alarm
OH : Overheat alarm
SV : Servo alarm
MALM: Memory alarm
B.4.12
Reading the CNC
Alarm Status
B.4.12.1
Except Power Mate