B–61863E/15
4. PMC PARAMETERS SETTING AND
DISPLAY (PMCPRM)
PMC OPERATION (CRT/MDI)
485
[PMC–SC/SC3/SC4 on SETTING screen]
PMC PRM (SETTING) MONIT RUN
PROGRAMMER ENABLE = 0(0:NO 1:YES)
LADDER START (RAM) = 0(0:MANUAL 1:AUTO)
RAM WRITE ENABLE = 0(0:NO 1:YES)
SIGNAL TRACE START = 0(0:MANUAL 1:AUTO)
SIGNAL ANALYS START = 0(0:MANUAL 1:AUTO)
DATA TBL CNTL SCREEN = 0(0:YES 1:NO)
FUNC KEY INP(CUSTOM) = 0(0:AVAL 1:IGNORE)
DEBUG FUNC START = 0(0:MANUAL 1:AUTO)
SIGNAL TRIGGER START = 0(0:MANUAL 1:AUTO)
TRANS LADDER (ONLEDT)= 0(0:MANUAL 1:AUTO)
INITPMC–MDI SCREEN = 0(0:YES 1:NO)
[ NO ] [ YES ] [ ] [ ] [ ]
(K17. 1)
(K17. 2)
(K17. 4)
(K17. 5)
(K17. 6)
(K17. 7)
(K18. 0)
(K18. 1)
(K18. 2)
(K18. 3)
(K18. 7)
* The bracketed addresses show the related KEEP RELAYs.
[PMC–PA3 on SETTING screen]
PMC PRM (SETTING) MONIT RUN
PROGRAMMER ENABLE = 0(0:NO 1:YES)
LADDER START = 0(0:AUTO 1:MANUAL)
RAM WRITE ENABLE = 0(0:NO 1:YES)
SIGNAL TRACE START = 0(0:MANUAL 1:AUTO)
DATA TBL CNTL SCREEN = 0(0:YES 1:NO)
SIGNAL TRIGGER START = 0(0:MANUAL 1:AUTO)
[ NO ] [ YES ] [ ] [ ] [ ]
(K17. 1)
(K17. 2)
(K17. 4)
(K17. 5)
(K17. 7)
(K18. 2)
* The bracketed address show the related KEEP RELAYs