NOTE
1 Relay search, relay coil search, and functional instruction
search are started from the current screen. If the relay, relay
coil, or instruction is not found by the end of the ladder
program, search is performed from the beginning of the
ladder program to the step at which search was started. If
still not found, ”NOT FOUND” is displayed.
2 Display of some instructions may differ from that for FANUC
LADDER.
The above also applies when modifying the ladder
mnemonics.
N0105 NOT FOUND
AND X0000.2
11. PMC PROGRAMMER (DPL/MDI)
(ONLY FOR THE Power Mate)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
628
P–G, personal–computer FANUC LADDER Ladder mnemonics editing
(a) RD.NOT.STK
(b) TMR timer–number
(c) DEC code–signal–address
(PRM) decode–instruction
RD.N.STK
SUB 03 TMR
P001 timer–number
SUB 04 DEC
P001 code–signal–address
P002 decode–instruction
1 Changing an instruction
(a) Display the instruction to be changed.
(b) Enter a new instruction.
(c) Press the <ALTER> key.
(Example) <OR>, <Y32.4>, <ALTER>
N1234
AND R0123.4
Before change
N1234
OR Y0032.4
After change
CAUTION
If changing the instruction causes the memory capacity to
be exceeded, the <ALTER> key is ignored without changing
the instruction.
2 Deleting an instruction
(a) Display the instruction to be deleted.
(b) Press the <DELET> key.
The instruction is deleted and the next instruction is displayed.
11.4.3
Modifying the Ladder
Mnemonics