1. GENERAL
B–61863E/15
PMC OPERATION (CRT/MDI)
428
(c) When the password is correctly specified, the protection is
released and the corresponding operation becomes available. See
Table 1.7 (a). If the password is incorrectly specified, the
message “FALSE PASSWORD” is displayed.
NOTE
The sequence program is cleared by turning on the power
with the X and O keys being held down, whether password
protection is specified or not.
(5) Special password
Ę : Usable
: See Note.
n : Not usable
Power
Mate/
FS21A
FS20/
FS21B/
FS0i A
FS18A FS16A FS16B
FS18B
FS16C
FS18C
FS21i FS16i
FS18i
FS0i B
FS15B FS15i
PA1
PA3
RA1
RA3
SA1, SA2
SA3
SB, SB2, SB3
SC, SC3
SB3
SC3
SB4
SC4
SB5
SC3
SB6 SC4 SA1
SA5
SA1
SB5
SB6
SB7
NB NB2 NB6
n
f
n
f f f
NOTE
Usable editions
PMC–SB4 : Series 4066 Edition 08 or later
PMC–SC4 : Series 4068 Edition 07 or later
Edit card : Series 4073 Edition 06 or later
When a password beginning with the character # is set for RW
password, the subprogram after P1500 can be edited in spite of the
protection by this password.
LADDER <<MAIN>> PROGRAM:(STEP SEQUENCE DEMO PROGRAM) MONIT STOP
P1500 ( ) USER PROGRAM NO.1
LEVEL1 LEVEL2 LEVEL3
V P0001 V P0002 V P0004 V P0005 V P0006 V P0007
V P0008 V P0009 V P0014 V P0015 V P0016 V P0017
V P0021 V P0022 V P0024 V P0025 V P0026 V] P0027
⋅⋅⋅⋅ ⋅ ⋅
⋅⋅⋅⋅ ⋅ ⋅
V P1500 V P1501 V]P1502
Example 1)
When the cursor is positioned to the subprogram P1500 and [ZOOM]
key is pressed, this subprogram P1500 can be edited in spite of the
protection by the password.
Example2)
When the cursor is positioned to the subprogram P1 and [ZOOM] key
is pressed, if the protection by the password is not released, the
message ”KEY IN PASSWORD(R/W)” is displayed and this
subprogram can be edited by inputting a correct password.