B–61863E/15
5. EDITING OF SEQUENCE
PROGRAM (EDIT)
PMC PROGRAMMER (CRT/MDI)
557
(8) [CONDNS] : Compress the sequence program in 1KB units.
The detail will be explained chapter 5.6.2.
(9) [CLRPRM] : Clears each parameter data.
The detail will be explained chapter 5.6.3.
(10) [CLREXT] : Clears the expand nonvolatile memory (valid for
PMC–SC/SC3/SC4/NB/NB2)
CAUTION
When using a system that incorporates flash ROM, clear the
flash ROM before writing to it. If the power is turned on again
without performing this operation, sequence program data
is not cleared.
Compresses the sequence program in 1KB units.
(1) [CONDNS] : Compresses the unused area in the message, symbol,
or comment area in the sequence program in 1KB
units when the capacity of the unused area extends
1KB. The unused area, which is the size less than
1KB, will not be compressed.
Clears each PMC parameter.
The function of the key is as follows:
(1) [CLRTMR] : Clears timer data.
(2) [CLRCNT] : Clears counter data.
(3) [CLRKPR] : Clears keep relay data.
(4) [CLRDT] : Clears data table.
(5) [CLRALL] : Clear all data described in the above (1) to (4).
CAUTION
1 These functions require the same condition as PMC data
setting in operation. For [CLRALL], all conditions are
required. See ”Chapter II. 4. PMC PARAMETER SETTING
AND DISPLAY”.
2 Contents of E addresses are not cleared by [CLRALL].
5.6.2
Compress the
Sequence Program
5.6.3
Clearing the PMC
Parameter