B–61863E/15
L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
APPENDIX
1551
The PMC specification of Series 0i–A is the same as PMC–SA1/SA3 for
Series 21–B. However, the following function is not supported.
– The memory card cannot be used on the I/O Screen of PMC.
In other words, the ladder program and the PMC parameter cannot be
input or output on the PMC screen with a memory card.
Please use the BOOT screen when you input or output the ladder program
with a memory card.
Please use the FANUC floppy disk cassette, the Handy File or
PC(personal computer) when you input or output the PMC parameter.
The on–line function of FANUC LADDER–II or FANUC LADDER–III
is not supported.
In PMC–NB6 for Series 15i–MODEL A/B, there is compatibility as
follows.
Data/Application Compatibility
Ladder Program Compatible between Model A and B
PMC Parameter Compatible between Model A and B
PMC C Language Application Compatible between Model A and B
Each data/applications in Model A can be available in Model B.
Each data/applications in Model B may not be available in Model A in the
future because the fuctions depend on CNC feature like the window
function may be improved.
L.4.3
Limited Function
L.5
COMPATIBILITY OF
PMC BETWEEN
Series15i–MODEL A
AND B