B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1187
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
29
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 4*n, n is the number of
axes specified.)
(Data number)
—
(Data attribute)
M
(M: Input data)
Skip coordinate of the controlled axis
specified(4 bytes)
Signed binary
(A negative value is represented in 2’s
complement.)
Value
When the number of controlled axes is 4
10
Skip coordinate of the second axis
(4 bytes)
Signed binary
(A negative value is represented in 2’s
complement.)
Value
14
Skip coordinate of the third axis
(4 bytes)
18
Skip coordinate of the fourth axis
(4 bytes)
22
Skip coordinate of the first axis
(4 bytes)
Output data unit
Input system
Increment
system IS–B
Increment
system IS–C
Machining center
system
mm, deg
system
0.001 0.0001
system
Power Mate–D, F
inch system 0.0001 0.00001
Radius
specification
mm, deg
0.001 0.0001
Lathe
Diameter
specification
system
0.001 0.0001
system
Radius
specification
0.0001 0.00001
Diameter
specification
inch system
0.0001 0.00001