B–61863E/15
2. COMPONENT UNITS AND
CONNECTIONS
PMC PROGRAMMER (CRT/MDI)
517
(1) Connecting the debugging RAM module
a) PMC–SB, –SB2 and –SB3 : Connect the module to portion 3
shown in Fig. 2.1 (a).
b) PMC–SC and PMC–SC3 : Connect the module to portion 1
shown in Fig. 2.1 (b).
c) PMC–SA1, –SA2 and –SA3: Connect the module to portion 3
shown in Fig. 2.1 (c).
(2) Connecting the editing module for PMC–SA1, –SA2, –SA3, –SB,
–SB2 and –SB3 Connect the module to portion 3 shown in Fig. 2.1
(a).
(3) Connecting ROM
a) PMC–SB, –SB2 and –SB3 : Connect EPROM to portion 13
shown in Fig. 2.1 (a).
b) PMC–SC and PMC–SC3 : Connect the ROM module to
portion 1 shown in Fig. 2.1 (b).
c) PMC–SA1, –SA2 and –SA3: Connect EPROM to portion 16
shown in Fig. 2.1 (c).
Ę : Enabled
∆ : Enabled depending on the option
: Disabled
SA1 SA2 SA3 SB SB2 SB3 SC SC3
RAM module Ę Ę Ę Ę Ę Ę Ę Ę
Editing module Ę Ę Ę Ę Ę Ę
EPROM Ę Ę Ę Ę Ę Ę
ROM module ∆ ∆ Ę Ę
NOTE
1 When 24,000 optional PMC–SB2 and PMC–SB3 ladder
steps are available, 256K bytes of the ROM module can be
used. In this case, connect the ROM module to portion 3
shown in Fig. 2.1 (a).
2 Either a RAM module, editing module, or ROM module can
be connected to each board of PMC–SA1, –SA2, –SA3,
–SB, –SB2 and –SB3.
3 Either a RAM module or ROM module can be connected to
each board of PMC–SC and PMC–SC3.
(4) Connecting the off–line programmer
Connect the off–line programmer to the reader/punch interface on the
CNC. There are several connectors for the reader/punch interface on
the CNC. The connector to be used is specified during I/O processing
for the PMC. For details, see Section 7.
2.2
CONNECTING
COMPONENT UNITS