B–61863E/15
3. ADDRESS
PMC SEQUENCE PROGRAM
103
(1) R9000 (Operation output register for the ADDB, SUBB, MULB,
DIVB, and COMPB functional instructions)
The result is 0.
The result is a negative
value.
The result overflows.
R9000
76543210
(2) R9000 (Error output for the EXIN, WINDR, WINDW, MMCWR,
MMCWW, MMC3R, and MMC3W functional instructions)
The instruction ended
in error.
R9000
76543210
(3) R9002 to R9005 (Operation output registers for the DIVB functional
instruction)
The data remaining after the DIVB functional instruction is executed
is output.
(4) R9010 to R9027 (Interface area for the FNC9x functional
instruction) (PMC–SC only)
The area is provided as an interface between the FNC9x functional
instruction to be executed and a desired function.
R9010
R9011
R9012
R9013
R9014
R9015
Contents of the command to
be executed
Data output when the
processing is completed
Addresses of the control data for SUB90
Addresses of the control data for SUB91
97 96 95 94 93 92 91 90
97 96 95 94 93 92 91 90
76543210
R9026
R9027
Addresses of the control data for SUB97
3.3.1
Area Managed by the
System Program