B–61863E/15
5. FUNCTIONAL INSTRUCTIONS
PMC SEQUENCE PROGRAM
309
(a) Input data length address (two bytes)
Specifies the length of input data transferred from MMC. When
transfer is completed, the length of data actually transferred is stored.
The maximum data length is 32 bytes.
(b) Input data address
Specifies the area containing data transferred from MMC. An area
large enough for the specified input data length is required.
W1=0 : This value is usually set. W1 = 1 indicates that processing is
completed. As soon as processing is completed, specify
ACT=0.
W1=1 : This value is set when data transfer from MMC is completed or
if an error occurs.
If an MMC window transfer error occurs, the bit in the operation output
register is set to indicate the error. If an error occurs, the transferred data
is not stored in the input data area.
R9000
76543210
MMCWR error
The completion status information is specified in R9002 and R9003. The
completion codes and contents, W1, and error bits are as follows:
–11 ···Initialization at MMC is not completed.
(W1 = 0, R9000#0 = 0)
–10 ···Processing is in progress (W1 = 0, R9000#0 = 0)
0 ··· Processing is completed.(W1 = 1, R9000#0 = 0)
2 ··· Data length error (W1 = 1, R9000#0 = 1)
(0, a negative value, or a value exceeding 33 bytes was specified
for the data length. The length of data actually transferred
exceeded the specified value.)
6 ··· MMC is not provided (W1 = 1, R9000#0 = 1)
Refer to Sec. I–9.3.
5.49.4
Parameters
5.49.5
Processing Completion
(W1)
5.49.6
Operation Output
Register
5.49.7
Completion Status
Information
5.49.8
Notes when this
Functional Instruction
is Used in Subroutine