3. ADDRESS
B–61863E/15
PMC SEQUENCE PROGRAM
98
Operator’s panel I/O
module
JD1B
JD1A
48 input points
32 output points
(a) If DO alarm detection is not used
D No manual pulse generator:
Input X = “CM06I” and output Y = “CM04O”
D One manual pulse generator:
Input X = “CM13I” and output Y = “CM04O”
D Two manual pulse generators:
Input X = “CM14I” and output Y = “CM04O”
D Three manual pulse generators:
Input X = “CM15I” and output Y = “CM04O”
(b)If DO alarm detection is used
D Input X = “CM16I” and output Y = “CM04O” no matter how
many manual pulse generators are used
(3)Distribution I/O machine operator’s panels (A20B–8001–0721,
A20B–8001–0720, and A20B–8001–0210)
Operator’s panel I/O
module
JD1B
JD1A
8 override (and other) signal input points + 24 general–purpose input points + 64
matrix input points
64 output matrix points
(a) If DO alarm detection is not used
D No manual pulse generator:
Input X = “CM12I” and output Y = “CM08O”
D One manual pulse generator:
Input X = “CM13I” and output Y = “CM08O”
D Two manual pulse generators:
Input X = “CM14I” and output Y = “CM08O”
D Three manual pulse generators:
Input X = “CM15I” and output Y = “CM08O”
(b)If DO alarm detection is used
D Input X = “CM16I” and output Y = “CM08O” no matter how
many manual pulse generators are used