5. SETTING MENU (SETING)
B–61863E/15
PMC–NB6 MANIPULATION
692
Clicking the [GENERAL] soft key displays the following screen.
D PROGRAMMER ENABLE
YES: The built–in debug function is used.
NO: The built–in debug function is not used.
D AUTOMATIC LADDER START
AUTO: The sequence program is executed automatically when
the power is switched on.
MANUAL: The sequence program is executed by clicking the
sequence program execution soft key.
D SIGNAL STATUS WRITE ENABLE
YES: The online function can be used to enter data on the signal status
screen.
NO: The online function is prevented from entering data on the
signal status screen.
D DATA TABLE CONTROL SCREEN
YES: The PMC parameter data table control screen is displayed.
NO: The PMC parameter data table control screen is not displayed.
D SIGNAL TRACE START
AUTO: Trace function is executed automatically when the power
is switched on.
MANUAL: Trace function is executed by operating soft key.
5.1
SCREEN FOR
DISPLAYING
GENERAL SETTINGS
(GENERAL)