B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1200
(b) Specifying a CNC–controlled axis (data attribute)
Specify a CNC–controlled axis for which the voltage conversion
data for the load current is to be read. Data must be specified
according to the following table (Valid with the FS16A/18A and
FS16B (interface type A)):
Specification of CNC controlled–axis
Specified data Connector in the CNC
1
2
3
4
5
6
7
8
JV1 (MAIN BOARD)
JV2 (MAIN BOARD)
JV3 (MAIN BOARD)
JV4 (MAIN BOARD)
JV5 (OPTION BOARD)
JV6 (OPTION BOARD)
JV7 (OPTION BOARD)
JV8 (OPTION BOARD)
CAUTION
For general–purpose analog input
Other than the i series
The OPTION2 board is required. Analog input is performed
through the analog signal interface. For details, refer to the
description of the analog signal interface in the connection
manual (hardware).
i series
General–purpose analog input is not supported. Use the
I/O Link analog input module.
[Completion codes]
0 : A/D conversion data has been read normally.
3 : The data specified for the data number is invalid.
4 : The data specified for the data attribute is invalid, or the specified
axis number is greater than the number of controlled axes.
6 : No analog input module is connected.