7. OPERATION (PMC–SB7)
B–61863E/15
STEP SEQUENCE FUNCTION
1046
2. STATUS
When it is displayed with ”EXEC”, it means active. When it isn’t
displayed, it means inactive.
3. ELAPSE
The time when it is active state is displayed. The time is increasing
during active state.
4. MONITOR
It means that time monitor is settings.
In the message line, error messages or inquiry messages will be displayed
depending on the situation.
D T(x): monitoring timer number.
D OVER: an elapsed time is over monitoring time.
Search step
Time Monitor Setting screen
Program List Viewer screen Reset of time monitor error
Fig. 7.2.1.1 Soft keys of Step Sequence State Screen (Whole)
(a) Operation with Soft–keys
1 [LIST] Goes to Program List Viewer screen
The screen display is switched into the Program List Viewer
screen.
2 [SEARCH] Search for step
Searches the step. If you entered step number or symbol and press
[SEARCH] soft key, the step according to the proceeding string is
searched, and the display is updated so that the step is displayed at
the top.
3 [RESET]
For all of monitoring steps, the error status, which occurred by the
monitoring function, is canceled. If you want to cancel it
independently, do a ”Deletion of monitor” on the Time Monitor
Setting screen.
4 [MONIT]
The screen display is switched into the Time Monitor Setting
screen.
5 [<]
The screen display is switched into the PMC Main menu.
7.2.1.1
Operations