5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
160
Table 5 (a) Types and Processing of Functional Instructions (10) Part 3
Com-
Type
Com-
mand
SUB
Number
Description Series 0i Mate–MODEL A/B
Name
Number
PMC–SA1
SPE 72 End of subprogram
NOP 70 No operation (Net comment) f
: Not available f : Available
The execution time constant is a ratio of the execution time of a functional
instruction to the execution time of 10 basic instruction steps (1.5 µs).
Execution time constants are used when a ladder program is executed in
the separate mode.
Table 5 (b) Execution Time Constants of Functional Instructions (1)
Instruc-
SUB
Model
tion
Number
Processing
PMC–SB PMC–SC
END1 1 End of a first–level ladder program 171 1033
END2 2 End of a second–level ladder program 26 45
END3 48 End of a third–level ladder program - 0
TMR 3 Timer processing 19 33
TMRB 24 Fixed timer processing 19 34
TMRC 54 Timer processing 17 29
DEC 4 Decoding 21 28
DECB 25 Binary decoding 16 23
CTR 5 Counter processing 21 35
CTRC 55 Counter processing 18 26
ROT 6 Rotation control 37 53
ROTB 26 Binary rotation control 27 39
COD 7 Code conversion 20 29
CODB 27 Binary code conversion 19 29
MOVE 8 Data transfer after Logical AND 19 27
MOVOR 28 Data transfer after logical OR 13 19
COM 9 Common line control 11 14
COME 29 End of common line control 0.1 0.1
JMP 10 Jump 12 16
JMPE 30 End of a jump 9 11
PARI 11 Parity check 13 19
DCNV 14 Data conversion 25 37
DCNVB 31 Binary data conversion 132 233
COMP 15 Comparison 22 36
COMPB 32 Binary comparison 20 31
COIN 16 Coincidence check 21 36
SFT 33 Shift register 15 22