7
7.2 Parameter List
274
01301 Stored stroke check performed before
movement
#0 DLM : The stored stroke limit switching signals
<G104, G105> for each axial direction is,
disabled(0)/enabled(1)
#2 NPC : As part of the stroke limit check performed
before movement, the movement specified in
G31 (skip) and G37 (automatic tool length
measurement (for M series) or automatic tool
compensation (for T series)) blocks is checked
(0)/not checked (1)
#3 OTA : If the tool is already in the prohibited area at
power–up (or when the conditions of
interference check are satisfied), an alarm of
stored stroke check 2 (inside), stored stroke
limit 3, or interference check is, not raised
before a movement is made(0)/immediately
raised(1).
#4 OF1 : If the tool is moved into the range allowed on
the axis after OT alarm is raised by stored
stroke check 1, the alarm is not canceled
before a reset is made(0)/the OT alarm is
immediately canceled(1)
#5 OTS : If the stored stroke limit alarm is issued when
PRM1300#7 is set to 1, the stop position on
the axis is, before the boundary (0)/on the
boundary (1)
(The manual linear/circular interpolation option
is required.)
#7 PLC : Stored stroke check before movement is not
performed (0)/performed (1)
M series
01310 Stored stroke check <Axis>
#0 OT2 : Stored stroke check 2 for each axis is, not
checked (0)/ checked (1)
#1 OT3 : Stored stroke check 3 for each axis is, not
checked (0)/checked (1)
01320 Coordinate value I of stored stroke check 1 in
the positive direction on each axis
[Increment system]
<Axis>
01321 Coordinate value I of stored stroke check 1 in
the negative direction on each axis
[Increment system]
<Axis>
01322 Coordinate value of stored stroke check 2 in
the positive direction on each axis
[Increment system]
<Axis>
01323 Coordinate value of stored stroke check 2 in
the negative direction on each axis
[Increment system]
<Axis>
01324 Coordinate value of stored stroke check 3 in
the positive direction on each axis
[Increment system]
<Axis>