18. MAINTENANCE INFORMATION
885
(3) Count type
The type of a selected count method is specified.
After the cursor is placed on the count type of a target registration
number, pressing soft key [TYPE] displays the next count type as a soft
key. Select it and press soft key [EXEC].
Soft key
Meaning Display
[NO CNT] Not counting (suspended). —
[ ALL ] Always count. All times
[PWR ON] Count while the power is supplied. Power–on time
[ RUN ] Count while operation is under way. Operating
[ CUT ] Count while cutting is under way. Cutting
18.5.5 Parameter
Percentage to the service life of each item displayed on the periodic
maintenance screen [%]
8911
[Valid data range] 0 to 100
On the periodic maintenance screens, any remaining
service time value smaller than the specified percentage
to the service life is displayed in red for warning
purposes.
18.5.6 Registered data input/output
Registered data can be input/output through an external device.
These operations can be done on the status, setting, and machine system
menu screens.
EDIT *** ***** *** **** 19:27:05
[ ][ READ ][ PUNCH ][ ][ ]
[ ][ ][ ][ CAN ][ EXEC ]
D Data input/output operation
Set the EDIT mode, then press the [PUNCH] soft key to output data.
Set the EDIT mode, then press the [READ] soft key to input data.
(Information such as item names is registered.)