10. PMC
641
(2) Trace parameter screen (second page)
On the trace parameter screen (first page), press
PAGE
PAGE
.
a) Address setting
Set a signal address as a bit address. If you enter a byte
address, bits 0 to 7 of the entered address are input. Up to 32
signal addresses can be set.
b) Soft keys
D [DELETE] : Deletes the set address where
the cursor is placed.
D [SYMBOL]/[ADRESS] : Switches the setting address
between symbol display and
address display.
D [MV.UP] : Replaces the set address with
the upper line.
D [MV.DWN] : Replaces the set address with
the lower line.
D [DELALL] : Deletes all set addresses.
c) Trigger setting
When “SIGNAL TRANSITION” is set as the trace sampling
mode and “BOTH EDGE” is set as the sampling condition, you
can choose whether to use a set address as a trigger signal
for sampling. To the right of a signal address set as a trigger,
a “F” mark is indicated.
D [TRGON] : Turns on a trigger setting.
D [TRGOFF] : Turns off a trigger setting.