10
10.1 PMC–SB7
644
10.1.3.2 TIMER screen
This screen is used for setting timer time of the Timer instruction (SUB 3).
Page number (screen is scrolled by page key)
Timer number specified with the Timer instruction
Address referenced by the sequence program
Set a timer
period in ms.
Timer set time : Timer No. 1–8 is max. 1572.8 sec and its accuracy is
48ms. Timer No. 9 to 250 is max. 262.1 sec and its
accuracy is 8ms.
10.1.3.3 COUNTER screen
This screen sets and displays max. value of counter and current value of
the counter instruction (SUB 5).
Page No. (screen is scrolled by page key)
Max. value of counter (Minimum value is speci-
fied by counter)
Current value of counter
Counter
numbers
from 1 to 100
Address referenced by the sequence program
Counter number specified by the counter instruction