7. PARAMETERS
327
03704 Setting related to control on multiple spindles
#1 SS4 : The fourth serial spindle is, not
used(0)/used(1)
#2 OR4 : For the fourth serial spindle, the function for
controlling the spindle orientation of the stop
position external setting type is, not
used(0)/used(1)
#4 SSS : Synchronous spindle control by each spindle
is, not performed(0)/performed(1)
#5 SSY : Simple synchronous spindle control by each
spindle is, not performed(0)/performed(1)
#6 PCS : Under multi–spindle control, the third or fourth
position coder selection signal <G026#0, #1>
is, not used(0)/used(1)
#7 CSS : On the second to fourth spindles, Cs contour
control is, not performed(0)/performed(1)
PRM
3701#4, #5
PRM
4831–4834
PRM
4821–4824
PRM1023
03705 Gear shift of spindle
#0 ESF : The SF signal output condition is such that S
codes and SF are output with all S commands
(0)/not output when constant surface speed
control is used or the spindle speed is clamped
(1).
#1 GST : The SOR signal is used for spindle orientation
(0)/gear shift (1)
#2 SGB : The gear switching method is method A
(PRM3741–3743) (0)/ method B
(PRM3751–3752) (1)
#3 SGT : The gear switching method during G84 and
G74 is method A (0)/method B (1)
#4 EVS : With an S command, S codes and SF are not
output (0)/output (1).
#5 NSF : When an S code command is issued in
constant surface-speed control, SF is output
(0)/not output (1)
#6 SFA : The SF signal is output when gears are
switched (0)/irrespective of whether gears are
switched (1)
PRM
3705#5
M series
PRM3751,
3752
M series
M series
PRM3761,
3762
T series
M series
M series