10. PMC
673
10.2.3.6 Setting screen
Some PMC system parameters can be set on this screen.
(K17.5)
(K18.2)
(K18.6)
(K19.0)
(K17.4)
(K17.7)
(K19.6)
(K19.7)
(K17.0)
(K17.2)
(K19.2)
(K17.1)
NOTE The parenthesized values to the right of the screen indicate keep
relay addresses.
10.2.4 Input/output of PMC data
10.2.4.1 Start of the built-in type PMC programmer
When the PMC data are input/output with I/O device unit via reader/puncher
interface, the built-in type PMC programmer should starts by as following
operation.
: As following operation is not required when the data set from MDI.
1 Select the PMC screen
Press
SYSTEM
key and press [PMC] soft key.
2 Confirm to the built-in type PMC programmer is running.
PMC CONTROL SYSTEM MENU
SELECT ONE OF FOLLOWING SOFT KEYS
PMCLAD : DYNAMIC LADDER DISPLAY
PMCDGN : DIAGNOSIS FUNCTION
PMCPRM : PARAMETER (T/C/K/D)
RUN/STOP : RUN/STOP SEQUENCE PROGRAM
EDIT : EDIT SEQUENCE PROGRAM
I/O : I/O SEQUENCE PROGRAM
SYSPRM : SYSTEM PARAMETER
MONIT : PMC MONITOR
PMCLAD
[][][][][]
PMCDGN PMCPRM
MONIT RUN
parts are displayed, starts of the built-in type PMC programmer.
The card editor is not used on FS16 but it has PMC-SB system.
This case, [RUN/STOP] and [I/O] function can used but editing of
sequence program is impossible.
3 Keep relay K17.1 should set to “1” if the built-in type PMC programmer
is not start yet.