7. PARAMETERS
303
03004 Overtravel
#0 BSL : The block start interlock signal *BSL and
cutting are: disabled (0)/enabled (1)
#1 BCY : When more than one operation is performed
by one block command such as a canned
cycle, the block start interlock signal is
checked only at the beginning of the first cycle
(0)/checked at the beginning of every cycle (1)
#5 OTH : The hardware overtravel function is used (0)/
not used (1).
03006 Reference position return deceleration signal
#0 GDC : The address of the reference position return
deceleration signal is X009, X007 (0)/G196,
G197 (1).
#1 EPN : Workpiece number search signals are
assigned to PN1, PN2, PN4, PN8, and PN16
<G009> (0)/EPN0 to EPN13 <G024, G025>
(1)
#2 EPS : When a program is searched using the
workpiece number search function, it is started
by automatic operation start signal ST (when
automatic operation (memory operation) is
started) (0)/workpiece number search start
signal EPNS. (Search is not started by ST.) (1)
03010 Delay time of strobe signals MF, SF, TF, BF
[msec]
03011 Acceptable width of M, S, T and B function
completion signal (FIN) [msec]
03017 Output time of reset signal RST [16 msec]
03030 Allowable number of digits for the M code
(1 to 8)
03031 Allowable number of digits for the S code
(1 to 5)
03032 Allowable number of digits for the T code
(1 to 8)
03033 Allowable number of digits for the B code
(1 to 8)