OPERATION4. AUTOMATIC OPERATION
B–63684EN/01
418
(a) INPUT UNIT : Handle interrupt move amount in input unit system
Indicates the travel distance specified by handle
interruption according to the least input increment.
(b) OUTPUT UNIT : Handle interrupt move amount in output unit
system
Indicates the travel distance specified by handle
interruption according to the least command
increment.
(c) RELATIVE : Position in relative coordinate system
These values have no effect on the travel distance
specified by handle interruption.
(d) DISTANCE TO GO : The remaining travel distance in the current
block has no effect on the travel distance
specified by handle interruption.
The handle interrupt move amount is cleared when the low speed
reference position return (the first reference position return when power
is turned on) ends every axis.