c. Edge data
Data item E201 E202 E203 E204 E205
Judge angle for edge #6700 #6715 #6730 #6745 #6760
Piercing power #6701 #6716 #6731 #6746 #6761
Piercing frequency #6702 #6717 #6732 #6747 #6762
Piercing duty #6703 #6718 #6733 #6748 #6763
Piercing time #6704 #6719 #6734 #6749 #6764
Piercing gas press #6705 #6720 #6735 #6750 #6765
Piercing gas select #6706 #6721 #6736 #6751 #6766
Recovery distance #6707 #6722 #6737 #6752 #6767
Recovery feedrate #6708 #6723 #6738 #6753 #6768
Recovery frequency #6709 #6724 #6739 #6754 #6769
Recovery duty #6710 #6725 #6740 #6755 #6770
Tracing displacement #6711 #6726 #6741 #6756 #6771
d. Active E code
Data item —
Piercing data set No. #6030
Cutting data set No. #6031
3) Power control data operation by custom macros
System variables are assigned to data items to allow custom macros
to read and write power control data.
These system variables can be referenced by the macro executor. In
this case, the number used for reference is obtained by adding 100000
to the corresponding system variable used by custom macros.
For example, data a custom macro references by using #6550 can be
referenced by the macro executor by using #106550.
Data item E901 E902 E903 E904 E905 E906 E907 E908 E909 E910
Minimum power #6550 #6560 #6570 #6580 #6590 #6600 #6610 #6620 #6630 #6640
Power at feedrate of 0 #6551 #6561 #6571 #6581 #6591 #6601 #6611 #6621 #6631 #6641
Minimum frequency #6552 #6562 #6572 #6582 #6592 #6602 #6612 #6622 #6632 #6642
Frequency at feedrate of 0 #6553 #6563 #6573 #6583 #6593 #6603 #6613 #6623 #6633 #6643
inimum duty cycle #6554 #6564 #6574 #6584 #6594 #6604 #6614 #6624 #6634 #6644
Duty cycle at feedrate of 0 #6555 #6565 #6575 #6585 #6595 #6605 #6615 #6625 #6635 #6645
Allowable feedrate variation width #6556 #6566 #6576 #6586 #6596 #6606 #6616 #6626 #6636 #6646